To set up a console access service (CAS) port:
1. Log onto the CLI as an administrator.
--:- / cli->
2. Enter set_cas ports/serial_ports/ followed by a space and the number of the port you
want to configure (port 1 is used as an example).
--:- / cli-> set_cas ports/serial_ports/ 1
3. Enter show to view the status of port 1.
Selected items: 1
Port: 1
enable_cisco_rj45_pin-out = no
status = enabled
speed = 9600
parity = none
data_bits = 8
stop_bits = 1
flow_control = none
Type ls to see available sub-nodes.
--:#- [serial_ports/physical] cli->ls
cas/
data_buffering/
alerts/
power/
Type show to see the content of the page.
--:#- [serial_ports/physical] cli->
4. Enter set status=enabled, then enter show and save as shown to enable the configured
port and verify and save the configuration.
--:- serial_ports/physical cli-> set status=enabled
--:- serial_ports/physical cli-> show
--:- serial_ports/physical cli-> save
To enable a power management port:
1. Log onto the CLI as an administrator and enter set_power ports/serial_ports/ <port
number> to select a port with a PDU connected (port 3 is used as an example).
--:- / cli-> set_power ports/serial_ports/ 3